This blog contains answers to exercises set for students. While every effort is made to ensure that the information posted is correct, mistakes may occur from time to time.
Search This Blog
Thursday, May 19, 2016
Friday, May 06, 2016
Capacitor questions
(a)V across 200k resistor = IR
V= (2x105) (2x 10-5) = 4V
VC = E - VR = 6-4 = 2V
(b) Q=VC
Q = (2.0) (560 x 10-6) = 1.12 x 10-3 C
(c) W = ½ CV2
W = ½ (560 x10-6) (2)2 = 1.12 x 10-3
J
Sunday, May 01, 2016
Thursday, April 14, 2016
Tuesday, April 12, 2016
Monday, April 04, 2016
Friday, March 25, 2016
X - Questions markscheme
1. (a) (to
a maximum of 7 marks) e.g.
• X-ray source + detectors round patient …
• … rotated around patient …/ the signal /
X-ray passes through the
same section of the body from different directions.
same section of the body from different directions.
• … producing a (thin) slice / cross-section.
• Idea of absorption / less gets through /
more is absorbed …
• by dense material / bone / material of high
Z / High Z related to
materials such as bone / Low Z to materials such as soft tissue
materials such as bone / Low Z to materials such as soft tissue
• attenuation is by the photo-electric effect
• the possibility of using a contrast medium.
• better than a simple X-ray at
differentiating other organs.
• patient is moved a small distance and the
process is repeated /
process continues in a spiral.
process continues in a spiral.
• a computer (analyses the data) / identifies
the position of organ/bone …
• … and forms a 3-D image. 7
(b) • Patients are exposed to ionising
radiation. (1)
• (Ionising radiation) could cause cancer /
damage cells (1)
Plus a maximum of ONE from:-e.g.
(1)
• It’s expensive.
• Time consuming / uses valuable resources,
etc.. 3
[10]
2. (a) Low energy X-rays are absorbed by the skin
/ undesirable as can cause
damage / greater ionising (1) 1
damage / greater ionising (1) 1
(b) I
= I0e–µx (1) ln I = ln Io – µ x
Io =
(1) ln
Io = ln 347 + 250 × 0.025
Io = 1.79 × 105 Wm–2 (1) 3
Io =
Io = 1.79 × 105 Wm–2 (1) 3
(c) P
= I × A (0)
P = 347 × Ï€ × (0.10 × 10–2)2 (1)
P = 1.09 × 10–3 W (1) 2
P = 347 × Ï€ × (0.10 × 10–2)2 (1)
P = 1.09 × 10–3 W (1) 2
(d) (i) P = 18 × 100 / 0.15 (1)
P = 12000 W (1) 2
P = 12000 W (1) 2
(ii) 12000
/ 7.5 × 1017 (= 1.6 × 10–14 J = energy of each electron) (1)
0.5 m v2 = 1.6 × 10–14 (0)
v = 1.9 × 108 ms–1 (1) 2
0.5 m v2 = 1.6 × 10–14 (0)
v = 1.9 × 108 ms–1 (1) 2
(iii) tube current = 7.5 × 1017 × 1.6 × 10–19 = 0.12 A (1)
V × I = 12000 (1)
V =12000 / 0.12 = 100,000 V or 100 kV (1) 3
V × I = 12000 (1)
V =12000 / 0.12 = 100,000 V or 100 kV (1) 3
[13]
3. Formation
of image to a max 3 e.g.
X-rays are detected by a film /
scintillation counter etc., (1)
High ‘Z’ means high attenuation / low transmission
[Allow atomic mass / nucleon number] (1)
shadow on the film / reference to exposure after attenuation (1)
Reference to photoelectric effect / energy range around 1–100keV /
absorption ∞ Z3 (1)
High ‘Z’ means high attenuation / low transmission
[Allow atomic mass / nucleon number] (1)
shadow on the film / reference to exposure after attenuation (1)
Reference to photoelectric effect / energy range around 1–100keV /
absorption ∞ Z3 (1)
Explanation of the use of a
contrast medium to a max.4 e.g.
X-rays do not differentiate / show up
soft tissues well …(1)
… as similar absorption / ‘Z’ is similar / ‘Z’ is low for these tissues. (1)
Contrast medium has high ‘Z’ / absorbs X-rays strongly.(1)
It is usually taken orally / as an enema / can be injected.(1)
… as similar absorption / ‘Z’ is similar / ‘Z’ is low for these tissues. (1)
Contrast medium has high ‘Z’ / absorbs X-rays strongly.(1)
It is usually taken orally / as an enema / can be injected.(1)
Example of type of structure that
can be imaged to a max.1 e.g.
digestive tract / throat / stomach.(1) to
a max. 8
[8]
Wednesday, March 23, 2016
y12 Assessed Homework
Young’s Slit - Assessed Homework.
Name___________________________________
Multiple choice questions
Circle the correct answer
1 Path
difference is measured in (1
mark)
A Degrees
B Metres
C Radians
D Wavelengths
2 Choose
the best combination for an experiment to produce an interference pattern with
light using two slits. (1
mark)
|
Answer
|
D
|
λ
|
a
|
|
A
|
2cm
|
600nm
|
0.5mm
|
|
B
|
2m
|
500nm
|
0.5mm
|
|
C
|
5m
|
6 x 10-9 m
|
2cm
|
|
D
|
2m
|
200nm
|
0.25mm
|
3 In a
Young’s slit experiment a coherent source of light of wavelength 600 nm is
used. The slits are 0.4mm apart and the screen is 1.2m from the sources. The
fringe separation is
A 1.8 x 10-3
mm
B 18 mm
C 1.8 x 10-3
m
D 18 cm (4
marks)
4. In the
pattern formed by a Young’s slit experiment the distance from the central
fringe to the 10th bright fringe is 3.44cm. If the screen is 2m form
the sources and λ = 0.589 µm the slit separation is
A 3.4 mm
B 2.9 mm
C 0.34 mm
Work for y13 - Thursday 24/3 answers will be here on Friday
1. Full-body
CT scans produce detailed 3-D information about a patient and can identify
cancers at an early stage in their development.
(a) Describe
how a CT scan image is produced, referring to the physics principles involved.
........................................................................................................................
........................................................................................................................
........................................................................................................................
........................................................................................................................
........................................................................................................................
........................................................................................................................
........................................................................................................................
........................................................................................................................
........................................................................................................................
........................................................................................................................
[7]
(b) State and explain two reasons
why full-body CT scans are not offered for regular checking of healthy
patients.
........................................................................................................................
........................................................................................................................
........................................................................................................................
........................................................................................................................
[3]
[Total 10 marks]
2. In order to take an X-ray
photograph, the X-ray beam is passed through an aluminium filter to remove low
energy X-ray photons before reaching the patient.
(a) Suggest
why it is necessary to remove these low-energy X-rays.
........................................................................................................................
........................................................................................................................
[1]
(b) The
average linear attenuation coefficient for X-rays that penetrate the aluminium
is 250 m–1. The intensity of an X-ray beam after travelling through 2.5
cm of aluminium is 347 W m–2.
Show
that the intensity incident on the aluminium is about 2 × 105 W m–2.
[3]
(c) The X-ray beam at the filter has a
circular cross-section of diameter 0.20 cm. Calculate the power of the X-ray
beam emerging from the aluminium filter. Assume that the beam penetrates the
aluminium filter as a parallel beam.
power =
............................ W
[2]
(d) The
total power of X-rays generated by an X-ray tube is 18W.
The efficiency of conversion of kinetic energy of the electrons into X-ray photon energy is 0.15%.
The efficiency of conversion of kinetic energy of the electrons into X-ray photon energy is 0.15%.
(i) Calculate
the power of the electron beam.
power = ..................... W
[2]
(ii) Calculate the velocity of the
electrons if the rate of arrival of electrons is 7.5 × 1017 s–1. Relativistic effects may be
ignored.
velocity = .....................
m s–1
[2]
(iii) Calculate
the p.d. across the X-ray tube required to give the electrons the velocity
calculated in (ii).
p.d.= ........................ V
[3]
[Total 13 marks]
. Describe the use of a contrast medium, such as barium, in the imaging of internal body structures. Your answer should include
• how
an image of an internal body structure is produced from an X-ray beam
• an
explanation of the use of a contrast medium
• examples
of the types of structure that can be imaged by this process.
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
.................................................................................................................................
[Total 8 marks]
Tuesday, March 15, 2016
Y12 Challenge question
Solution will be published at 4 pm
Thursday, March 10, 2016
X Ray imaging question
X-ray (photons
penetrate patient (1)
attenuation by different media / bones attenuate more than soft tissue (1)
less X-ray reach film under bone / shadow effect (1)
intensity of X-rays is proportional to darkening of film / ref. To fogging or
blackening (1)
attenuation by different media / bones attenuate more than soft tissue (1)
less X-ray reach film under bone / shadow effect (1)
intensity of X-rays is proportional to darkening of film / ref. To fogging or
blackening (1)
X-ray photons hit crystals / atoms
in intensifying layer (1)
atoms become excited / fluorescence occurs (1)
emitting light (photons) (1)
detail: as they return to ground state (1)
so extra fogging of film (1)
detail: metal backing stops X-rays passing through / film more sensitive to light
than X-rays / most X-rays pass through the film / double sided / photographic
film / more contrast but not clearer (1)
atoms become excited / fluorescence occurs (1)
emitting light (photons) (1)
detail: as they return to ground state (1)
so extra fogging of film (1)
detail: metal backing stops X-rays passing through / film more sensitive to light
than X-rays / most X-rays pass through the film / double sided / photographic
film / more contrast but not clearer (1)
Response is quicker / less X-rays
needed (1)
so less exposure (1) to maximum of 8 8
so less exposure (1) to maximum of 8 8
[8]
Wednesday, March 09, 2016
Subscribe to:
Posts (Atom)